Industrial scales, electronic balances, calibration weights and moisture analysers - order online, telephone 01842 751633 or email sales@blakeandboughton.co.uk for advice, a quotation or to place an order

cart-icon

My Cart

Items: 0 items
Value: £0.00

user-icon

Kern DBS 60-3 60g x 0.001g / 0.01% Moisture Analyser

Our Price: £1,430.69 + VAT (£1,716.83 inc VAT)

Do you require a calibration certificate – traceable to National Standards?

Price: £35

Description

Moisture Analyser With High-quality Single-cell Weighing System For Outstanding Stability, Reliability And Response Speed

· Suitable for samples with low moisture content, e.g. plastics
· Backlit Graphic display, digit height 15 mm

1 Drying process active
2 Previous drying time
3 Current temperature
4 Unit for displaying the results
5 Current moisture content in %
6 Active heating profile

· Excellent temperature control thanks to halogen technology, suitable for temperature-sensitive samples
· Internal memory for automatic sequence of 10 complete drying processes and 100 drying processes carried out
· The last value measured remains on the display until it is replaced by a new measurement
· Password protection to prevent manipulation of stored settings, data, etc
· 10 sample plates included
· Protective working cover included with delivery
· GLP compliant

Heating Technology: Halogen-quartz Glass Heater, 400 Watt

Capacity / Readability / Moisture Content Display: 60g / 0.005g / 0.1%/1%

Drying Temperature: 50 – 200°C

Drying Mode: Standard Drying, Drying in Levels, Gentle Drying, Rapid Drying

Weighing Units: 5 Moisture, 5 Dry Mass, ATRO* Dry Mass, ATRO* Moisture, Gram

Calibration: External

Interface: RS-232C (cable not supplied), USB

Power Supply: AC 100V to 120V (3A) or AC 200V to 240V (1.5A), 50/60 Hz, Approx. 400W

Downloads

PDF-Download

We endeavour to deliver your goods to you as fast as we can. A large percentage of our orders are delivered in 3 - 5 working days (all mainland UK postcodes except IV, AB and KW) but some goods can take longer if they are delivered direct from the manufacturer or if the item is made to order. Please note, IV, AB and KW postcodes and non-mainland UK including Northern Ireland can take longer. Please give us a call if your order is urgent to verify the delivery time or see if a faster delivery is possible (additional costs may apply for larger orders).

The following delivery charges may apply per order:
  • £6.00 + VAT – Mainland UK
  • £30.00 + VAT – UK non-mainland incl. N. Ireland (5 – 7 working days)
  • £40.00 + VAT – Ireland (7 – 10 working days)

Reviews

There are no reviews yet.

Be the first to review “Kern DBS 60-3 60g x 0.001g / 0.01% Moisture Analyser”

Your email address will not be published. Required fields are marked *

Frequently Asked Questions

Please see below for answers to frequently asked questions.

A calibration certificate proves the accuracy of your weighing equipment. It is very likely that if accuracy matters in your workplace, certification will be required by your industry regulators. They are straightforward to get hold of though. Just ask our team.

If you are trading or transacting anything by weight, you will probably need to demonstrate your weighing equipment is verified for trade use. This gives your customers confidence in your business and will make sure buying and selling run smoothly. We can help get you with relevant approvals for your equipment.

The answer will vary depending on how your equipment is used. As a minimum, we typically recommend once a year but our team can provide advice based on your individual circumstances.

The International Organization of Legal Metrology (OIML) has established standards for the classification of calibration test weights. Varying from E0 & E1, which are the most accurate to M2 which are commonly used for calibrating platform scales, floor scales and other industrial weighing instruments.

As a rough guide we have listed desired accuracy against class below.

+/- 0.1% – UNclassed Proof Load Test Weights
+/- 0.05% – M3 (Check/calibrate coarse scales)
+/- 0.005% – M1 (Check/calibrate standard scales)
+/- 0.0015% – F2 (Check/calibrate portable balances)
+/- 0.0005% – F1 (Check/calibrate precision balances)
+/- 0.00015% – E2 (Check/calibrate analytical balances)

The choice of weight class depends on the intended use and the level of accuracy required for a particular application. If you’re unsure, talk to our team who can advise you on the right class for your equipment.

If you’re sending a scale back to us for recalibration, it is ideal to use the original packaging. If this is not available choose a sturdy well-padded box to avoid shocks. Where possible, protect the load sensor by removing the weighing pan and any under-pan support and pack these separately in the box. You may be able to use the equipment’s locking pins or screws too.

Do ensure all the paperwork, including your contact details, is included to ensure we can return it once calibration is complete.

Need help? Speak to one of our experts Contact Us

Sign up To Our Newsletter
For Exclusive Deals & news!

Right Menu Icon